General specifications
Dimensions excl. antenna: 55 mm by 147 mm by 90 mm
Weight, battery activated: approximately 220 g
Battery: water -activated
Voltage: 19 V
Transmitter frequencies: 403 MHz, 1680 MHz
Windfinding alternatives: GPS, Loran-C, Alpha/Com-VLF
Meteorological sensors
PTU sensors are individually factory calibrated.
Pressure: BAROCAP® Capacitive aneroid
Measuring range: 1060 hPa to 3hPa (mb)
Resolution: 0.1 hPa
Accuracy:
Reproducibility (1): 0.5 hPa
Repeatability of calibration (2): 0.5 hPa
Temperature: THERMOCAP® Capacitive bead
Measuring range: +60 °C to - 90 °C
Resolution: 0.1 °C
Accuracy:
Reproducibility (1): 0.2 °C up to 50 hPa, 0.3 °C for 50-15 hPa, 0.4°C above 15 hPa level
Repeatability of calibration (2): 0.2 °C
Lag: < 2.5 s (6 m/s flow at 1000 hPa)
Humidity: HUMICAP® Thin film capacitor
Measuring range: 0 to 100 % RH
Resolution: 1 % RH
Lag: 1 s (6 m/s flow at 1000 hPa, +20 °C)
Accuracy:
Reproducibility (1): <3 %RH
Repeatability of calibration (2): 2 %RH
(1) Data based on WMO International Radiosonde Comparison, Phases I, II, and III (WMO/TD no 195 and 451)
(2) Standard deviation between two successive calibrations