General specifications Dimensions excl. antenna: 55 mm by 147 mm by 90 mm Weight, battery activated: approximately 220 g Battery: water -activated Voltage: 19 V Transmitter frequencies: 403 MHz, 1680 MHz Windfinding alternatives: GPS, Loran-C, Alpha/Com-VLF Meteorological sensors PTU sensors are individually factory calibrated. Pressure: BAROCAP® Capacitive aneroid Measuring range: 1060 hPa to 3hPa (mb) Resolution: 0.1 hPa Accuracy: Reproducibility (1): 0.5 hPa Repeatability of calibration (2): 0.5 hPa Temperature: THERMOCAP® Capacitive bead Measuring range: +60 °C to - 90 °C Resolution: 0.1 °C Accuracy: Reproducibility (1): 0.2 °C up to 50 hPa, 0.3 °C for 50-15 hPa, 0.4°C above 15 hPa level Repeatability of calibration (2): 0.2 °C Lag: < 2.5 s (6 m/s flow at 1000 hPa) Humidity: HUMICAP® Thin film capacitor Measuring range: 0 to 100 % RH Resolution: 1 % RH Lag: 1 s (6 m/s flow at 1000 hPa, +20 °C) Accuracy: Reproducibility (1): <3 %RH Repeatability of calibration (2): 2 %RH (1) Data based on WMO International Radiosonde Comparison, Phases I, II, and III (WMO/TD no 195 and 451) (2) Standard deviation between two successive calibrations